SFMTA and Calgary Tester v1.0.69

Requested Changes
-   On test results, label DCU input and output tests with X connector name
-   Add additional DCU output tests:
    •   Add X6/1 - ADA Push Button Red LEDs
    •   Add X6/5 - LED Step Lighting
    •   Add X6/6 - Obstruction Buzzer
    •   Add X6/10 - DCU Command Step to go Up
    •   Add X6/11 - DCU Command Step to go Down
    •   Add X6/12 - DCU Command Gap Filler to Retract
    •   Add X6/13 - DCU Command Gap Filler to Extend
-   Add additional DCU input tests (subject to hardware modification):
    •   Add Step Overcurrent (Step Obstructed) DCU Input test on X3/21
Other Changes
-   Try to improve auto start test for SFMTA by delaying serial port connection until after DCU has been reset
-   Fix display order of tests to better match execution order
-   Test all DCU outputs using DCU's "output override" function