SFMTA and Calgary Tester v1.0.69
Requested Changes
- On test results, label DCU input and output tests with X connector name
- Add additional DCU output tests:
• Add X6/1 - ADA Push Button Red LEDs
• Add X6/5 - LED Step Lighting
• Add X6/6 - Obstruction Buzzer
• Add X6/10 - DCU Command Step to go Up
• Add X6/11 - DCU Command Step to go Down
• Add X6/12 - DCU Command Gap Filler to Retract
• Add X6/13 - DCU Command Gap Filler to Extend
- Add additional DCU input tests (subject to hardware modification):
• Add Step Overcurrent (Step Obstructed) DCU Input test on X3/21
Other Changes
- Try to improve auto start test for SFMTA by delaying serial port connection until after DCU has been reset
- Fix display order of tests to better match execution order
- Test all DCU outputs using DCU's "output override" function